配置型号包含以下特性:
RF & Microwave Network AnalyzersCal Kits20GHz <= 50GHz1kHz <= 100kHz2.92mm-Female (Plug)Accessory特性 | 参数 |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
Low Frequency (range) | 1kHz <= 100kHz |
Connector Type | 2.92mm-Female (Plug) |
Form Factor | Accessory |
High-end automatic VNA calibration units
Covering 8.5 GHz to 50 GHz, 2 and 4 ports, configurable.
The models cover the frequency range from 9 kHz to 50 GHz, with type N, 3.5 mm, 2.92 mm and 2.4 mm connectors depending on the frequency range. They are available with 2 or 4 ports. With re-connection, also multiport calibration of R&S®ZNBT, R&S®ZNB and switch matrix systems is supported. The R&S®ZN-Z51 ranges up to 8.5 GHz and enables each port to be configured individually: the standard versions are 3.5 mm(f) and type N(f) ports, but each port can be ordered individually as 3.5 mm (f or m), N (f or m), 7/16 (f or m) or 4.3-10.
Key Features |
Wide frequency range 9 kHz to 50 GHz |
Virtually no warm-up time required |
Auto-detection and USB control |
Multiport calibration supported |
Benefits | |
Wide Frequency Range; Covering a total of 9 kHz to 50GHz | The frequency range of the ZN-Z5x automatic calibration units supports the main frequency ranges of the Rohde and Schwarz network analyzers. The high frequency models offer lower frequencies of 100 kHz and 9 kHz to cover a broad range of applications. |
Configurable Test Port Types; Support of mixed connector systems | Each port on the 8.5 GHz ZN-Z51 models can be individually configured. Each port can be permanently changed to N(m), 3.5 mm (m,f), 7/16 (m,f), 4.3-10 (f) |
Auto Configuration and Detection; Plug and play calibration | The ZN-Z5x calibration units are detected automatically via the USB connection. All required data is transferred to the VNA. When starting the calibration, the port assignment can be found with a keystroke. The calibration can be launched with minimum effort, time and highest reliability. |
Specifications | ||||||
ZN-Z5x Automatic Calibration Units | ||||||
Model Overview | ||||||
Model | Order Number | Type | Frequency Range | Connector Type | Number of Ports | Description |
ZN-Z50 | 1335.6904.30 | Calibration unit 50 Ohms | 9 kHz to 9 GHz | 3.5 mm (f) | 2 ports | for; ZVA/T ZNB/T ZNC ZND ZNL |
ZN-Z50 | 1335.6904.32 | Calibration unit 50 Ohms | 9 kHz to 26.5 GHz | 3.5 mm (f) | 2 ports | for; ZVA/T ZNB/T ZNC ZND ZNL |
ZN-Z51 | 1319.5507.32 | Calibration unit | 100 kHz to 8.5 GHz | 3.5 mm(f) | 2 ports | -- |
ZN-Z51 | 1319.5507.34 | Calibration unit | 100 kHz to 8.5 GHz | 3.5 mm(f) | 4 ports | -- |
ZN-Z51 | 1319.5507.72 | Calibration unit | 100 kHz to 8.5 GHz | N(f) | 2 ports | It is possible to individually configure each port of this Calibration Unit. Each Port can be permanently adapted; N(m) 3.5mm (m,f) 7/16 (m,f) 4.3-10 (f). |
ZN-Z51 | 1319.5507.74 | Calibration unit | 100 kHz to 8.5 GHz | N(f) | 4 ports | It is possible to individually configure each port of this Calibration Unit. Each Port can be permanently adapted; N(m) 3.5mm (m,f) 7/16 (m,f) 4.3-10 (f). |
ZN-Z52 | 1335.6991.30 | Calibration unit 50 Ohms | 100 kHz to 26.5 GHz | 3.5 mm (f) | 4 ports | for; ZVA/T ZNB/T ZNC ZND ZNL |
ZN-Z53 | 1335.7046.32 | Calibration unit 50 Ohms | 100 kHz to 26.5 GHz | 3.5 mm (f) | 2 ports | for; ZVA/T ZNB/T ZNC ZND ZNL |
ZN-Z53 | 1335.7046.72 | Calibration unit 50 Ohms | 100 kHz to 18 GHz | N (f) | 2 ports | for; ZVA/T ZNB/T ZNC ZND ZNL |
ZN-Z54 | 1335.7117.92 | Calibration unit 50 Ohms | 9 kHz to 40 GHz | 2.92 mm (f) | 2 ports | for; ZVA/T ZNB/T ZNC ZND ZNL |
ZN-Z55 | 1335.7181.42 | Calibration unit 50 Ohms | 9 kHz to 50 GHz | 2.4 mm (f) | 2 ports | for; ZVA/T ZNB/T ZNC ZND ZNL |