配置型号包含以下特性:
Power Supplies / Electronic LoadsDC Power Supplies <50V请参考资源中的资料文档或查看产品总览。
如果您想了解更多,请 联系,我们的团队将为您提供帮助。
The EX354D and EX354Tv provide high levels of power (up to 305 watts) in a compact and attractive case style. High resolution controls allow precise setting of voltage and current levels which are indicated on accurate and legible digital meters. Excellent line and load regulation are matched by low noise and good transient response. High power efficiency ensures that the unit remains cool without any fan noise.
The EX354Tv has, in addition, an Auxiliary ‘logic voltage’ output with a 5A current capability. To reflect the increasing usage of low-voltage logic devices, this output can be preset between 1.5 volts and 5 volts via a front panel control. The total power capability is 280 watts for the dual supply and 305 watts for the triple.
The EX series incorporates separate digital voltage and current meters on each main output. The meters use bright 14mm (0·56”) LED displays and have an update rate of 4 per second providing near instantaneous response. Simultaneous metering of voltage and current provides accurate information “at a glance” and avoids any possibility of misinterpretation. When an output switch is set to “off”, the current limit setting is displayed enabling conditions to be set before the load is connected. With the right-hand main output off, the right-hand meters can be used to momentarily display the preset Auxiliary voltage and current limit.
The EX series has been designed to meet the stringent requirements of relevant IEC standards for safety and EMC, including harmonics emissions. All outputs are intrinsically short circuit proof, and are protected against external voltages and reverse currents.
Key Features |
Provides high levels of power at surprisingly low cost |
Mixed-mode regulation |
Constant voltage or constant current operation |
Low voltage auxiliary output |
Simultaneous digital metering |
Single, dual or triple outputs |
Safe and reliable |
Specifications | |||
EX Series DC Power Supply | |||
Model Overview | |||
Model | EX354TV | EX354D | EX354T |
Voltage Range | 0V to 35V minimum | 0V to 35V minimum | 0V to 35V minimum |
Current Range | 0A to 4A minimum | 0A to 4A minimum | 0A to 4A minimum |
Operating Mode | Constant voltage or constant current with automatic cross-over | Constant voltage or constant current with automatic cross-over | Constant voltage or constant current with automatic cross-over |
Load Regulation | <0.01% of maximum output for 90% load change | <0.01% of maximum output for 90% load change | <0.01% of maximum output for 90% load change |
Line Regulation | <0.01% of maximum output for 10% line change | <0.01% of maximum output for 10% line change | <0.01% of maximum output for 10% line change |
Output Impedance | Typically <5mΩ in constant voltage mode. Typically >50kΩ in constant current mode | Typically <5mΩ in constant voltage mode. Typically >50kΩ in constant current mode | Typically <5mΩ in constant voltage mode. Typically >20kΩ in constant current mode |
Output Protection: | Output will withstand up to 40V forward voltage | Outputs will withstand forward voltages up to 40V | Outputs will withstand forward voltages up to 40V |
Output Terminals | Universal 4mm safety binding posts on 19mm (0.75”) pitch | Universal 4mm safety binding posts on 19mm (0.75”) pitch | 4mm terminals on 19mm (0.75") pitch |
Ripple & Noise (20MHz bandwidth) | Typically <2mVrms, <10mVpk-pk (CV mode) | Typically <2mVrms, <10mVpk-pk (CV mode) | Typically <2mV rms, <10mV pk-pk, (CV mode) |
Voltage Setting | By coarse and fine controls | By coarse and fine controls | By coarse and fine controls |
Current Setting | By single logarithmic control | By single logarithmic control | By single logarithmic control |
AC Input | 110V - 240V AC ± 10%, 50/60Hz. Installation Category II | 110V - 240V AC ± 10%, 50/60Hz. Installation Category II | 110V - 240V AC ± 10%, 50/60Hz. Installation Category II |
Power Consumption | 500VA max | 500VA max | 500VA max |
Operating Range | +5ºC to +40ºC, 20% to 80% RH | +5ºC to +40ºC, 20% to 80% RH | +5ºC to +40ºC, 20% to 80% RH |
Storage Range | −40ºC to + 70ºC | −40ºC to + 70ºC | −40ºC to + 70ºC |
Environmental | Indoor use at altitudes up to 2000m, Pollution Degree 2 | Indoor use at altitudes up to 2000m, Pollution Degree 2 | Indoor use at altitudes up to 2000m, Pollution Degree 2 |
Safety | Complies with EN61010-1. EMC: Complies with EN61326 | Complies with EN61010-1. EMC: Complies with EN61326 | Complies with EN61010-1. EMC: Complies with EN61326 |
Weight | 4.3 kg | 4.3 kg | 4.3 kg |
Specifications | |
EX354TV DC Power Supply | |
Model Overview | |
Features | Parameters |
Auxiliary Logic Output: | |
Voltage | Variable <1.5V to >5V by front panel control |
Meter Voltage Accuracy | 0.3% ± 1 digit |
Current Limit | 5A minimum |
Output Protection | Output will withstand up to 7V forward voltage. Diode clamp reverse protection for currents up to 3A |
Load Regulation | <0.5% for 90% load change |
Line Regulation | <0.1% for 10% line voltage change |
Ripple & Noise (20MHz bandwidth) | Typically <2mVrms, <10mVpk-pk (CV mode) |
Transient Response | Typically <200µs to within 50mV of set level for 90% load change |
Temperature Coefficient | Typically <100ppm/ºC |
Status Indication | UNREG lamp |