配置型号包含以下特性:
Oscilloscopes & Logic AnalyzersOscilloscopes < 1GHz2Not Applicable10MHz <= 100MHz特性 | 参数 |
---|---|
Channel/Port Count | 2 |
Maximum Sample/Data Rate | Not Applicable |
High Frequency (range) | 10MHz <= 100MHz |
In today's complex systems, a meter measurement just doesn't give enough detail to determine the cause of a fault. Signal anomalies, dropouts and glitches that might cause a machine to go down, are best displayed with an oscilloscope. The Fluke 124 ScopeMeter meet today's need of simultaneously measuring and checking waveforms.
For industrial, electronic or electro mechanical applications, the compact Fluke 124 Industrial ScopeMeter is the rugged solution for industrial troubleshooting and installation applications. It features 40MHz bandwidth, Connect-and-View triggering automatically displays stable waveforms of virtually any signal and a dual DMM and a paperless recorder to get virtually any job done.
It is a truly integrated test tool in one affordable, easy-to-use instrument. Find fast answers to problems in machinery, instrumentation, control and power systems.
Key Features |
Dual-input TrendPlot™ paperless recorder plots and displays the actual ,minimum, maximum and average of any measurement up to 16 days with a resolution of 1.5 hours |
Connect-and-View™ advanced triggering that recognizes signal patterns and automatically sets up and continuously adjusts triggering time base and amplitude |
Measurements include: Vdc, Vac, Vac+dc, Vpeak max, Vpeak min, Vpeak to peak, frequency, positive and negative pulse width, positive and negative duty cycle, Aac, Adc, Aac+dc (with optional probe), phase, temperature (with optional probe), dBV, and dBm into 50Ω and 600Ω |
Shielded test leads for oscilloscope, resistance and continuity measurements |
Cursor measurements |
Full bandwidth, VPS40 10:1 40 MHz probe included |
Memory save and recall of 20 instrument screens with user set-ups and user text |
600V CAT III safety certified |
Optically isolated RS-232 interface |
Up to seven hours battery operation |
Rugged compact case, IP51 drip and dust proof |
Industrial Networks bus health testing (125) |
Measure harmonics and power, VA, VAR, W, PF (125) |
Applications |
Industrial Troubleshooting |
Installations |
Specifications | |||
Fluke 124 Industrial Scopemeter; Fluke 124, 40MHz | |||
Model Overview | ScopeMeter 120 Series | ||
Model | Fluke 125 | Fluke 124 | Fluke 123 |
Bandwidth | 40 MHz | 40 MHz | 20 MHz |
Max. real time sample rate | 25 MS/s | 25 MS/s | 25 MS/s |
Max equivalent time sample rate | 2.5 GS/s | 2.5 GS/s | 1.25 GS/s |
Display | 10.2 cm monochrome LCD | 10.2 cm monochrome LCD | 10.2 cm monochrome LCD |
Digital persistence | – | – | – |
Envelope mode | Yes | Yes | Yes |
Waveform compare | – | – | – |
Max record length in Scope mode: | |||
in Scope Record mode | 512 min/max points per input | 512 min/max points per input | 512 min/max points per input |
Number of inputs | 2; opt. Isolated External Trig. thru ITP120 | 2; opt. Isolated External Trig. thru ITP120 | 2; opt. Isolated External Trig. thru ITP120 |
Number of digitizers | 2 | 2 | 2 |
Independently floating isolated inputs | – | – | – |
Input sensitivity | 5 mV/div. 500 V/div. | 5 mV/div. 500 V/div. | 5 mV/div. 500 V/div. |
Glitch capture | 40 ns | 40 ns | 40 ns |
Timebase range in scope mode | 10 ns/div 1 min/div. | 10 ns/div 1 min/div. | 20 ns/div 1 min/div |
Trigger types | Connect-and-ViewTM, Free Run, Single Shot, Edge, Video | Connect-and-ViewTM, Free Run, Single Shot, Edge, Video | Connect-and-ViewTM, Free Run, Single Shot, Edge, Video |
Scope measurements | As 124 + Power, VA, VAR, PF, RPM, Vpwm; THD | Cursor + 26 Automatic measurement | 26 automatic measurements |
Bus health test function | For standard industry buses | – | – |
Waveform mathematics | Harmonics mode | – | – |
Power measurements | Power, VA, VAR, PF, Vpwm | – | – |
Scope Record trigger modes | – | – | – |
Capture last 100 screens | – | – | – |
Dual input TrendPlot | Yes, with cursors | Yes, with cursors | Yes |
Memory for screens/ set-ups | 20 | 20 | 10 |
Memory for recordings | 20 | 20 | 10 |
True-rms multimeter | Dual fully featured 5000 counts DMM | Dual fully featured 5000 counts DMM | Dual fully featured 5000 counts DMM |
Safety certified (EN61010-1) | 600 V CAT III (Instrument and included accessories) | 600 V CAT III (Instrument and included accessories) | 600 V CAT III (Instrument and included accessories) |
Battery (installed) | 7 hr Ni-MH (BP120MH) | 7 hr Ni-MH (BP120MH) | 7 hr Ni-MH (BP120MH) |
BHT190 bus health adapter set | Optional | – | – |
Line power | Adapter / Battery charger included (PM8907) | Adapter / Battery charger included (PM8907) | Adapter / Battery charger included (PM8907) |
Size | 23.2 cm x 11.5 cm x 5.0 cm | 23.2 cm x 11.5 cm x 5.0 cm | 23.2 cm x 11.5 cm x 5.0 cm |
Weight | 1.2 kg | 1.2 kg | 1.2 kg |
PC and printer interface | Using optional optically insulated adapter/cable OC4USB (USB) or PM9080 (RS-232) | Using optional optically insulated adapter/cable OC4USB (USB) or PM9080 (RS-232) | Using optional optically insulated adapter/cable OC4USB (USB) or PM9080 (RS-232) |