TThe THDP0100 and P5210A have the largest differential dynamic range capability from Tektronix, allowing users to safely measure up to ±6000 V. The THDP0100 supports bandwidths up to 100 MHz and slew rates up to 2500 V/ns at 1/1000 gain. These probes are supplied with two sizes of hook tips and have an overrange visual and audible indicator which warns the user when they are exceeding the linear range of the probe.
Key Performance Specifications:
- Bandwidths up to 200 MHz
- Up to 6000 V differential (DC + pk AC)
- Up to 2300 V common (RMS)
Key Features:
- Overrange Indicator
- Safety Certified
- Switchable Attenuation
- Switchable bandwidth limit
Applications:
- Floating measurements
- Switching power supply design
- Motor drive design
- Electronic ballast design
- CRT display design
- Power converter design and service
- Power device evaluation
Connectivity:
- BNC interface (P5200A probes)
- TekVPI® interface (TMDP and THDP Series probes)
- TekProbe® interface (P5202A, P5205A, and P5210A Series probes)
Specifications |
|
|
|
Model Overview |
|
|
|
Model | TMDP0200 | THDP0200 | THDP0100 |
Attenuation | 25X / 250X | 50X / 500X | 100X / 1000X |
Differential Voltage | 250X: ±750 V | 500X: ±1500 V | 1000X: ±6000 V |
| 25X: ±75 V | 50X: ±150 V | 100X: ±600 V |
Common Mode Voltage | ±750 V | ±1500 V | ±6000 V |
Maximum Input Voltage-to-Earth | 550 V CAT I | 1000 V CAT II | 2300 V CAT I |
| 300 V CAT III | 600 V CAT III | 1000 V CAT III |
Bandwidth | 200 MHz | 200 MHz | 100 MHz |
Rise Time | <1.8 ns | <1.8 ns | <3.5 ns |
Slew Rate | <275 V/ns at 1/250 gain | <650 V/ns at 1/500 gain | <2500 V/ns at 1/1000 gain |
Input Impedance at the Probe Tip | 5 MΩ || <2 pF | 10 MΩ || <2 pF | 40 MΩ || <2.5 pF |
Typical CMRR | DC: > -80 dB | DC: > -80 dB | DC: > -80 dB |
| 100 kHz: > -60 dB | 100 kHz: > -60 dB | 100 kHz: > -60 dB |
| 3.2 MHz: > -30 dB | 3.2 MHz: > -30 dB | 3.2 MHz: > -30 dB |
| 100 MHz: > -26 dB | 100 MHz: > -26 dB | 100 MHz: > -26 dB |
Cable Length | 1.5 m | 1.5 m | 1.5 m |