The VIAVI Solutions® OLP-88 TruePON tester is the ideal tool for field technicians dealing with G-PON and XGS-PON network service activation and for support teams charged with resolving service complaints and identifying the sources of issues. TruePON uses G-PON data analysis for real-time measurement of fiber optic cable insertion loss, downstream and upstream power levels, ODN class, and for instantaneous identification of OLT-ID ONU/ONT-ID as well as rogue ONUs causing service issues.
VIAVI Solutions® OLP-88 TruePON 测试仪是处理 G-PON 和 XGS-PON 网络服务启动的现场技术人员以及负责解决服务投诉和识别问题来源的支持团队的理想工具。 TruePON 使用 G-PON 数据分析来实时测量光纤电缆插入损耗、下行和上行功率等级、ODN 类别,并实时识别 OLT-ID ONU/ONT-ID 以及导致服务问题的恶意 ONU。
Key Features:
- 适用于 B-PON、E-PON、G-PON、XGS-PON 和 10G-EPON 网络的波长选择性直通模式功率计
- 提供 1310/1490 nm、1310/1490/1550 nm 和 1270/1310/1490/1577 nm 版本
- 自动 ODN 类别侦测和功率级通过/失败分析
- 在用损耗测量
- OLT 识别; ONU/ONT序号提取;恶意和外来 ONU 检测
- 低插入损耗 (<1.5 dB)
- 使用内建跳线显微镜或选购的 P5000i 探头自动进行通过/失败光纤检测分析
- 轻松产生专业认证报告
立即前往挑选更多 : 光功率计
Specifications |
|
|
|
OLP-88 and OLP-88P |
|
|
|
Functionality |
|
|
|
Model | Version 2327/26 (1310/1490) | Version 2327/36, 2328/36 (1310/1490/1550) | Version 2327/37 (1270/1310/1490/1577) |
B-PON (ITU-T G983.x) | X | X | X |
G-PON (ITU-T G984.x) | X | X | X |
E-PON (IEEE 802.3av) | X | X | X |
XGS PON (ITU-T G.9807.1) |
|
| X (Option) |
10G-EPON (IEEE 802.3av) |
|
| X (Option) |
RF Video Signals 1550nm |
| X |
|
Specifications |
|
|
|
OLP-88 and OLP-88P |
|
|
|
FTTx Mode |
|
|
|
Model | Version 2327/26
(1310/1490)
| Version 2327/36, 2328/36
(1310/1490/1550)
| Version 2327/37
(1270/1310/1490/1577)
|
Upstream 1270 nm, Burst Mode
Power Measurement Range
Max Permitted Input Level
Spectral Passband
|
|
|
-40 to +13 dBm (1)(2)
+17 dBm
1250 to 1330 nm
|
Upstream 1310 nm, Burst Mode
Power Measurement Range
Max Permitted Input Level
Spectral Passband
|
-40 to +13 dBm (1)
+17 dBm
1290 to 1330 nm
|
-40 to +13 dBm (1)
+17 dBm
1290 to 1330 nm
|
-40 to +13 dBm (1)
+17 dBm
1250 to 1330 nm
|
Downstream 1490 nm
Power Measurement Range
Max Permitted Input Level
Spectral Passband
G-PON Data Analysis at 1490 nm
|
-45 to +7 dBm
+9 dBm
1450 to 1495 nm
-30 to +7 dBm
|
-45 to +7 dBm
+9 dBm
1450 to 1495 nm
-30 to +7 dBm
|
-45 to +7 dBm
+9 dBm
1450 to 1495 nm
-30 to +7 dBm
|
Downstream 1577 nm (2)
Power Measurement Range
Max Permitted Input Level
Spectral Passband
|
|
|
-45 to +13 dBm
+15 dBm
1528 to 1610 nm
|
RF Video Signals 1550 nm (3)
Power Measurement Range
Max Permitted Input Level
Spectral Passband
|
|
-45 to +26 dBm
+27 dBm
1540 to 1560 nm
|
|
Notes:
(1) Burst mode: -35 to +13 dBm
(2) For OLP-88 2327/37 version only, requires XGS-PON option 2327/94.04
(3) For OLP-88 2327/36, and 2328/36 versions only
Specifications |
|
OLP-88 and OLP-88P |
|
Instrument |
|
Display Resolution | 0.01 dBm/0.001 μW |
Display Units/Information | dB, dBm, with pass/fail |
ORL | >60 dB |
Threshold Sets | ITU-T G.984.3 or user-specific thresholds |
Pass-through Insertion Loss (4) | <1.5 dB |
Power Uncertainty (4) | ±0.5 dB |
Calibrated Wavelengths | 1270/1310/1490/1550/1577 nm |
Notes:
(4) At 23°C ±3°C, at 1310/1490/1550/1577 nm, at −7 dBm
Specifications |
|
OLP-88 and OLP-88P |
|
General |
|
Display | High-contrast 3.5 in color LCD with touch-screen functionality |
Fiber Inspection Capability | With patch-cord microscope or external P5000i microscope (optional) |
Data Memory | Up to 10,000 PON results |
Data Readout | Via client USB interface |
Electrical Interfaces | 2 x USB host, 1x micro USB, Ethernet |
Wireless Interface | WiFi client (optional) |
Power Supply | 12 V, 2 A with interchangeable wall plug for EU, UK, US, and AU |
Battery | Li-ion pack 3.7 V, 20 Wh |
Battery Life (Li-ion battery pack) | >12 hr |
Optical Connectors | APC with SC switchable adapters (FC, ST and LC adapters optional) |
Recommended Recalibration Interval | 3 years |
Operating Temperature Range | –5˚ to +45˚C (23˚ to 113˚F) |
Storage Temperature Range | –25˚ to +55˚C (–13˚ to 131˚F) |
Specifications |
|
|
OLP-88 and OLP-88P |
|
|
Model | Dimensions (H x W x D) | Weight |
OLP-88 | 208 x 112 x 64 mm
8.2 x 4.4 x 2.5 in
| 750 g
1.6 lbs
|
OLP-88P | 208 x 153 x 64 mm
8.2 x 6.0 x 2.5 in
| 850 g
1.85 lbs
|
Specifications |
|
Ordering Information |
|
Part Number | Description |
2327/26 | OLP-88 TruePON tester, 1310/1490 nm |
2327/36 | OLP-88 TruePON tester, 1310/1490/1550 nm |
2327/37 | OLP-88 TruePON tester, 1270/1310/1490/1577nm |
2328/36 | OLP-88P TruePON tester with patchcord microscope, 1310/1490/1550 nm |
All OLP-88 and -88P TruePON testers include:
- APC connector and SC optical adapter (x2)
- SC2 soft shoulder case
- Quick-start manual and safety instructions
- RBP2 rechargeable LiON battery pack (3.7 V, 20 Wh) and PS4 power supply (12 V, 2 A)
Specifications |
|
OLP-88 and OLP-88P |
|
Accessories, Hardware/Sofware Options |
|
Software Options |
|
Part Number | Description |
2327/94.01 | OLP-88 Alien ONT detection |
2327/94.02 | OLP-88 GPON-ID test |
2327/94.04 | OLP-88 XGS-PON option (for 2327/37 only) |
Hardware Options |
|
2327/90.21 | WiFi option including USB WiFi adapter |
Accessories |
|
FBP-SD101 | P5000i digital analysis microscope with 4 tips (FBPT-SC, FBPT-LC, FBPTU25M, FBPT-U12M) |
2155/00.32 | ST switchable optical adapter for OLP-88 |
2155/00.05 | FC switchable optical adapter for OLP-88 |
2155/00.07 | LC switchable optical adapter for OLP-88 |
FITP-RCG1 | Kit, RBP2 rechargeable battery (Li ion) and FBPP-PS4 power supply (12 V) |
FBPP-PS4 | Power supply for SmartClass Fiber (12 V) |
FITP-RBP2 | Rechargeable battery for SmartClass Fiber (Li ion) |
FITP-UC4 | UC4 hands-free carrier for SmartClass Fiber |
FITP-UC4P | UC4P hands-free carrier for SmartClass Fiber with PCM |
FBPP-SCASE2 | SCASE2 soft shoulder case for SmartClass Fiber tools |