配置型号包含以下特性:
MultimeterData AcquisitionCounters & Function GeneratorsData Acquistion请参考资源中的资料文档或查看产品总览。
如果您想了解更多,请 联系,我们的团队将为您提供帮助。
The Keysight DAQM907A module Data Acquisition System allows great flexibility for a variety of sense and control applications. It combines two 8-bit ports of digital input and output, a 100 kHz gated totalizer, and two ±12V analog outputs - all on a single earth-referenced module. The analog outputs have two additional voltage/current sensing channels. The digital inputs and totalizer input may be included in a scan. Alarm limits for the digital and event counter inputs are evaluated continuously, capturing and logging alarm conditions even between scans.
Key Features |
16 bits of digital input and output |
100 kHz totalizer input |
Two +/-12V analog outputs plus two voltage/current sensing channels |
Benefits | |
Digital Input/Output | Use the digital outputs with an external power supply to control microwave switches and attenuators, solenoids, power relays, indicators, and more. Use the digital inputs to sense limit switch and digital bus status. There are no complex handshake modes; reads and writes are initiated either from the front panel or the bus. |
Totalize Input | Count events from devices like photo interrupters, limit switches, and Hall-effect sensors. It keeps an updated total which can be read via the front panel or programmatically at any time. With 26 bits of resolution, it can count events at full speed for nearly 45 minutes without an overflow. |
Analog Output | Use the two electronically calibrated analog outputs to source bias voltages to your device under test, to control your analog programmable power supplies, or use the outputs as setpoints for your control systems. The outputs are programmed directly in volts, either from the front panel or from the bus. |
Specifications | |
Data Acquisition System | |
Series Overview | |
Model | Description |
Mainframe | |
DAQ970A | Data Acquisition System Mainframe with USB and LAN |
DAQ973A | Data Acquisition System Mainframe with USB, LAN and GPIB |
Option Z54 | ANSI Z540 compliant calibration |
Modules | |
DAQM900A | 20-Channel solid-state multiplexer |
DAQM901A | 20-Channel armature multiplexer |
DAQM902A | 16-Channel reed multiplexer |
DAQM903A | 20-channel actuator/general purpose switch |
DAQM904A | 4 x 8 Two-wire matrix switch |
DAQM905A | Dual 4-Channel RF multiplexer, 50 Ω |
DAQM907A | Multifunction module |
DAQM908A | 40-Channel single-ended multiplexer |
DAQM909A | 4-Channel simultaneous sampling digitizer |
Accessories | |
11062A | Kelvin clip set |
34307A | 10-pack of J-type thermocouples |
34308A | 5-pack of 10 kΩ thermistors |
34905-60001 | Kit of 10 SMB-to-BNC adapter cables, 50 Ω |