The MN213 is a general purpose AC current probe designed for DMMs and other measuring instruments with current input. It has a 1000:1 ratio and an output of 1mA per Amp in the primary (inside the jaw).
The MN213 has integral 5 ft (1.5m) leads terminated by shrouded banana plugs.
The MN213 has protective diodes across the output that limit the voltage in open secondary situations.
Key Features |
Small compact size |
Measurement ranges from 100mA to 240A |
Frequency response to 10kHz |
UL approved for both US and Canada |
Designed to EN61010, 600V CAT III |
Jaw opening accommodates 250kcmil cables |
Constructed with UL94VO flame retardant material |
Double insulated construction |
Specifications |
|
AC Current Probe Model MN213 |
|
Features | Parameters |
Maximum Conductor Size | 0.78" (20mm), bus bar 20x5mm |
Current Range | 200Arms AC |
Measurement Range | 0.5 to 240A |
Output | 5ft (1.5m) lead with 4mm safety banana plug |
Transformation Ratio | 1000:01:00 |
Output Signal | 1mA/A AC (200mA @ 200A) |
Accuracy 50/60Hz | 1% ± 0.5A @ 200A |
Frequency Range | 40Hz to 10KHz |
Phase Shift at 50Hz | 2.5° @ 200A |
Open Secondary Voltage | Limited to <6V with diodes |
Load Impedance | 1Ω, 10Ω max with derating |
Overload | 240A for 10 min ON, 30 min OFF |
Dimensions
(H x W x D)
| 5.47 x 2.00 x 1.18”
(139 x 51 x 30mm)
|
Weight With 24” (610mm) Sensor | 6.3 oz (180g) |
Operating Temperature | 14° to +131°F
(-10° to +55°C)
|
Storage Temperature | -40° to +158°F
(-40° to +70°C)
|
Operating Humidity | 90% RH |
Pollution Degree | 2 |
Ingress Protection (Ip) | IP40 |
EMC | EN 61326-1 |
Safety Compliance | EN/IEC 61010-1 600V CAT III
EN/IEC 61010-032
UL Listed
|
Specifications |
|
AC Current Probe Model MN200 Series |
|
Model Overview |
|
Part Number | Description |
2115.75 | AC Current Probe Model MN213 |
2115.77 | AC Current Probe Model MN251 |
2115.79 | AC Current Probe Model MN253 |
2115.81 | AC Current Probe Model MN255 |
2115.84 | AC Current Probe Model MN291 |