The 5700A family has set the standard for multifunction calibrator performance in calibration laboratories around the world. Now the time has come to advance this best-in-class calibrator, taking advantage of twenty-first century technology and usability.
The Fluke Calibration 5730A High Performance Multifunction Calibrator is the culmination of years of engineering development, customer research and industrial design, to bring to market the new “gold standard” in electrical multifunction calibration.
The 5730A calibrates a wide range of digital multimeters, up to long-scale 8.5 digit DMMs, as well as RF voltmeters when equipped with the wideband option. But this new model features improved specifications that will help you increase test uncertainty ratios (TURs) and increase test confidence. What’s more, the improved specifications will reduce your need to guardband, giving you confidence and peace of mind in your calibrations.
The 5730A is designed for calibration professionals who require the most accurate dc/lf signals available in a multifunction calibrator, as well as those who simply want the best calibrator available. Metrologists in national laboratories, the military, third party calibration laboratories, and corporate users with high-end workload will value the performance and reliability of the 5730A. All 5730A calibrators are traceable to international standards and are produced in the factory with ISO/IEC 17025 accredited calibrations. Specifications are stated to the standard Fluke Calibration 99 % confidence level (as well as 95 % confidence level) to support easy measurement comparisons according to international quality standards. Specifications are absolute and include the uncertainty of the calibration standards used. No additional analysis is required.
Key Features |
Improved performance specifications for ac voltage, ac current and resistance |
6.5 inch VGA capacitive touch screen with full color graphical user interface |
Visual Connection Management™ output terminals guide connections |
Graphical user interface in nine languages |
Compatible with 52120A and 5725A amplifiers |
Full MET/CAL® compatibility with 5700A and 5720A procedures |
Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards; 30 MHz and 50 MHz wideband output options available |
Specifications | |
5730A High Performance Multifunction Calibrator | |
Features | Parameters |
Voltage DC | |
Range: | 0 to ±1100 V |
Best 1 Year, 95% Specification: | 3.5 ppm + 2.5 µV |
Voltage AC | |
Range: | 22 µV to 1100V 10 Hz to 1 MHz |
Best 1 Year, 95% Specification: | 42 ppm + 8 µV |
Resistance | |
Range: | 0 to 100 MΩ 18 values in x1 and x1.9 |
Best 1 Year, 95% Specification: | 6.5 ppm |
Current DC | |
Range: | 0 to ±2.2A (0 to ±11A with 5725A; 0 to ±100 A with 52120A) |
Best 1 Year, 95% Specification: | 35 ppm + 7 nA |
Current AC | |
Range: | 9 µA to 2.2A, 10 Hz to 10 kHz (9 µA to ±11A with 5725A; 9 µA to ± 120 A with 52120A) |
Best 1 Year, 95% Specification: | 103 ppm + 8 nA |
Wideband AC Voltage Option | |
Range: | 300 µV to 3.5V 10 Hz to 50 MHz |
Best 1 Year, 99% Specification: | 0.4% + 500 µV |
Warm Up Time | Twice the time since last warmed up, to a maximum of 30 minutes |
Settling Time | Less than 5 seconds for all functions and ranges except as noted |
Standard Interfaces | IEEE-488 (GPIB) RS-232 USB 2.0 Device Ethernet 5725A 52120A Phase lock in (BNC) Phase reference out (BNC) |
Temperature | Operating: 0 °C to 50 °C Calibration: 15 °C to 35 °C Storage: -40 °C to 75 °C |
Operating Altitude | 2000 m maximum |
Relative Humidity | Operating: < 80% to 30 °C < 70% to 40 °C < 40% to 50 °C |
Storage:< 95%, non-condensing. | |
Safety | IEC 61010-1: 300 V CAT II, Pollution Degree 2 |
Analog Low Isolation | 20 V |
Electromagnetic Environment | IEC 61326-1: Controlled |
Line Power | 47 Hz to 63 Hz; ±10% 100 V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V |
Power Consumption | 300 VA |
Dimensions | Height: 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet |
Width: 43.2 cm (17 in), standard rack width | |
Depth: 64.8 cm (25.5 in), overall; 59.4 cm (23.4 in), rack depth | |
Weight | 27 kg 62 lbs |
Absolute Uncertainty Definition | 5730A uncertainty specifications include; Stability Temperature coefficient Linearity Load regulation and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated |
Specification Confidence Interval | 99% and 95% |
Specifications | |
5730A High Performance Multifunction Calibrator | |
Model Overview | |
Model | Description |
5730A | Multifunction Calibrator |
5730A/03 | Multifunction Calibrator with 30 MHz Wideband AC Voltage Option |
5730A/05 | Multifunction Calibrator with 50 MHz Wideband AC Voltage Option |
5730A/S | Multifunction Calibrator with No Front Panel USB Port |
Optional Accessories | |
52120A | Transconductance Amplifier |
5725A | Amplifier |
5730A-7002 | Low Thermal EMF Cables with Banana Plugs |
5730A-7003 | Low Thermal EMF Cables with Spade Connectors |
Y5737 | 5790B and 5700A/5720A Rack Mount Kit. Includes 24 in. slides that allow for side ventilation |
Y5738 | 5730A Rack Ear Kit |
57XX/CASE | Transit Case for 57XXA Series |
Software | |
MET/CAL | MET/CAL Plus Calibration Management Software |
MET/TEAM | MET/TEAM Test Equipment Asset Management Software |