配置型号包含以下特性:
CalibrationCalibration Standards- AC请参考资源中的资料文档或查看产品总览。
如果您想了解更多,请 联系,我们的团队将为您提供帮助。
If you need increased performance, the Fluke 5520A Multi-Product Calibrator expands your workload coverage even further with improved accuracy in nearly all areas and with several additional features and functions
Key Features |
Lower output uncertainties to meet the requirements of 51 ⁄2 and 61 ⁄2 digit multimeters. |
Phase lock to simplify simulation of three-phase power. You may also sum the current from multiple 5520As to perform high current tests, such as direct calibration of current clamps or verification of current transformers. |
Current output expanded to 20A. Verify current clamps to 1000A using the 5500A/COIL 50-Turn Coil accessory. |
Pressure measurement using any of the 27 Fluke 700 Series Pressure Modules, which cover ranges from 0-10”(0-2.5 kPa) H2O to 0-10,000 PSI (0-70,000 kPa) to calibrate pressure gauges, transducers and other indicators. |
Temperature measurement, making it easy to record environmental conditions present at the time of calibration, as required by all quality standards. |
Improved phase and frequency accuracy and the capability to reference the 5520A to an external 10 MHz frequency standard to support calibrating frequency counters. |
Wider capacitance calibration andresistance ranges |
Increased compliance voltage in current output modes. |
Expanded ac Volt*Hertz capacity to 330V at 100 kHz. |
Specifications | |
5520A High Performance Multi-Product Calibrators | |
Features | Parameters |
Voltage DC | Range: 0 to ±1020V Best 1 Year Specification: ±12 ppm of setting |
Current DC | Range: 0 to ±20.5A Best 1 Year Specification: ±100 ppm of setting |
Resistance | Range: 0 to 1100 MΩ Best 1 Year Specification: ±28 ppm of setting |
Voltage AC | Range: 1 mV to 1020V 10 Hz to 500 kHz, Sine Best 1 Year Specification: ±120 ppm of setting |
Current AC | Range: 29 mA to 20.5A 10 Hz to 30 kHz, Sine Best 1 Year Specification: ±0.06% of setting |
Capacitance | Range: 0.19 nF to 110 mF Best 1 Year Specification: ±0.25% of setting |
Thermocouple Source and Measure | Range: -250°C to +2316°C (11 types) Best 1 Year Specification: ± 0.14°C of setting |
RTD Source | Range: -200°C to +630°C (8 types) Best 1 Year Specification: ±0.03°C of setting |
DC Power | Range: 10.9 mW to 20.5 kW Best 1 Year Specification: ±0.023% of setting |
AC Power | Range: 10.9 mW to 20.5 kW 45-65 Hz, PF=1 Best 1 Year Specification: ±0.08% of setting |
Phase | Range: 0 to ± 179.99° 10 Hz to 30 kHz Best 1 Year Specification: ±0.07° of setting |
Frequency | Range: 0.01 Hz to 2.0 MHz Best 1 Year Specification: ±25 ppm of setting |
Specifications | |
5520A High Performance Multi-Product Calibrators | |
Features | Parameters |
Warm up Time | Twice the time since last warmed up, to a maximum of 30 minutes |
Settling Time | Less than 5 seconds for all functions and ranges except as noted |
Standard Interfaces | IEEE-488 (GPIB), RS-232 |
Temperature Performance | Operating: 0°C to 50°C Calibration (tcal): 15°C to 35°C Storage: -20°C to 70°C |
Temperature Coefficient | Temperature coefficient for temperatures outside tcal ± 5°C is 10% of the 90-day specification (or 1-year, as applicable) per °C |
Relative Humidity | Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C Storage: <95%, non-condensing |
Altitude | Operating: 3,050m (10,000 ft) maximum Non-operating: 12,200m (40,000 ft) maximum |
Safety | 12,200m (40,000 ft) maximum |
Analog Low Isolation | 20V |
EMC | Designed to comply with IEC 61326-1/1997 |
Line Power | Line Voltage (selectable): 100V, 120V, 220V, 240V Line Frequency: 47 to 63 Hz Line Voltage Variation: + 10% about line voltage setting |
Power Consumption | 600 VA |
Dimensions | Height: 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit Width: 43.2 cm (17 in), standard rack width Depth: 47.3 cm (18.6 in) overall |
Weight (without options) | 22 kg (49 lbs.) |
Absolute Uncertainty Definition | 5500A and 5520A uncertainty specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated. |
Specification Confidence Interval | > 99% |
Specifications | |
5520A High Performance Multi-Product Calibrators | |
Model Overview | |
Model | Description |
5520A | High Performance Multi-Product Calibrator |
5520A-PQ | 5520A Multi-Product Calibrator with Power Quality Option |
5520A-PQ/ 3 | 5520A Multi-Product Calibrator with PQ and 300 MHz Scope Option |
5520A-PQ/ 6 | 5520A Multi-Product Calibrator with PQ and 600 MHz Scope Option |
5520A-PQ/ 1G | 5520A Multi-Product Calibrator with PQ and 1 GHz Scope Option |