配置型号包含以下特性:
CableAntenna & PIM AnalyzersElectromagnetic measurement tools请参考资源中的资料文档或查看产品总览。
如果您想了解更多,请 联系,我们的团队将为您提供帮助。
The Narda Nardalert XT D8862 Personal RF Monitor is designed to satisfy the needs of virtually all individuals who use an RF personal monitor. The Narda Nardalert XT D8862 is worn on the body to detect higher levels of radiation. The ultra-broadband sensors of the Narda Nardalert XT D8862 cover almost the entire usable RF spectrum in a single monitor with a frequency range of 100 kHz to 100 GHz.
The unique tri-sensor design of the Nardalert XT D8862 handles every possible signal format, from complex multi-signal communication environments to military platforms with both communications and radar signals.
The Nardalert XT D8862 closely conforms to AS/NZ 2772.1 (1998, draft) Occupational; DIN VDE 0848, Part 2, October 1991 Area 1 Occupational; ENV 50166-2 Occupational; and ICNIRP 1998 Occupational standards. The five flashing high-intensity LED level indicators can be seen while wearing the monitor, even outdoors in the sun. The adjustable alarm feature allows one alarm to be set at a level equal to the upper tier of two-tier standards, such as the “Occupational” or “Controlled” limits, while the second alarm can be set to the lower tier, such as the “Action” or “General Population” limits.
The audio alarm has two distinct sounds that are associated with the two different alarm thresholds. The user can select an audio alarm, a vibrator alarm, both audio and vibrator, or an optional remote vibrator. The remote vibrator on the Nardalert XT D8862 can be used in areas with high ambient noise when the user is wearing heavy clothing that would prevent the detection of the internal vibrator.
Key Features |
100 kHz to 100 GHz |
Shaped Frequency Response Matched to Your Standard |
Data Logger Records Continuously – more than 30,000 data points |
Five High-Intensity LED Level Indicators |
Tri-Sensor Handles All Types of Fields |
Two Adjustable Audio Alarms |
Adjustable Vibrator Alarm |
Long Battery Life |
Patented Design |
Specifications | |||
Nardalert XT RF Personal Monitor | |||
Model | 8860 | 8861 | 8862 |
Frequency Range | 100 kHz to 100 GHz | 10 MHz to 100 GHz | 100 kHz to 100 GHz |
Frequency Sensitivity | +3/-1 dB | +3/-1 dB | +3/-1 dB |
Sensors (All E-field) | Low-band surface area detector, diode Mid-band dipole, diode High-band thermocouple | Low-band surface area detector, diode Mid-band dipole, diode High-band thermocouple | Low-band surface area detector, diode Mid-band dipole, diode High-band thermocouple |
Alarm Indicators | LEDs: Five High Intensity Flashing, 2 Yellow, 3 Red Audio Alarm 1: Steady Tone Audio Alarm 2: Variable Tone Vibrator, Internal: Continuous Vibrator, Remote: Continuous | LEDs: Five High Intensity Flashing, 2 Yellow, 3 Red Audio Alarm 1: Steady Tone Audio Alarm 2: Variable Tone Vibrator, Internal: Continuous Vibrator, Remote: Continuous | LEDs: Five High Intensity Flashing, 2 Yellow, 3 Red Audio Alarm 1: Steady Tone Audio Alarm 2: Variable Tone Vibrator, Internal: Continuous Vibrator, Remote: Continuous |
Alarm Threshold | Alarm 1: Default Setting: 50% of Standard Range of Adjustment: 10% to 100% of Standard in increments of 5% Alarm 2: Default Setting: 200% of Standard Range of Adjustment: 200% of Standard Vibrator, Internal: Same Threshold as Alarm 1 Vibrator, Remote: Same Threshold as Alarm 1 | Alarm 1: Default Setting: 50% of Standard Range of Adjustment: 10% to 100% of Standard in increments of 5% Alarm 2: Default Setting: 200% of Standard Range of Adjustment: 200% of Standard Vibrator, Internal: Same Threshold as Alarm 1 Vibrator, Remote: Same Threshold as Alarm 1 | Alarm 1: Default Setting: 50% of Standard Range of Adjustment: 10% to 100% of Standard in increments of 5% Alarm 2: Default Setting: 200% of Standard Range of Adjustment: 200% of Standard Vibrator, Internal: Same Threshold as Alarm 1 Vibrator, Remote: Same Threshold as Alarm 1 |
LED Indicators | 10% 20% 50% 100% 200% of Standard | 10% 20% 50% 100% 200% of Standard | 10% 20% 50% 100% 200% of Standard |
CW Overload | 3000% of Standard or Guidance | 3000% of Standard or Guidance | 3000% of Standard or Guidance |
Peak Overload | 32 dB above Standard or Guidance | 32 dB above Standard or Guidance | 32 dB above Standard or Guidance |
ELF Immunity | 6,000 V/m | 100,000 V/m | 6,000 V/m |
Battery Type / Life | Type: 1 x AA Alkaline Life: 800 hrs. with LEDs and Alarms OFF | Type: 1 x AA Alkaline Life: 800 hrs. with LEDs and Alarms OFF | Type: 1 x AA Alkaline Life: 800 hrs. with LEDs and Alarms OFF |
Temperature | Operating: -10°C to +55°C Non-Operating: -20°C to +60°C | Operating: -10°C to +55°C Non-Operating: -20°C to +60°C | Operating: -10°C to +55°C Non-Operating: -20°C to +60°C |
Weight | 157 g 5.5 oz | 157 g 5.5 oz | 157 g 5.5 oz |
Size (H x W x D) | 10.5 cm x 7.6 cm x 3.5 cm 4.12" x 3.0" x 1.37" | 10.5 cm x 7.6 cm x 3.5 cm 4.12" x 3.0" x 1.37" | 10.5 cm x 7.6 cm x 3.5 cm 4.12" x 3.0" x 1.37" |
Accessories Supplied | Pocket Clip Belt Clip Plastic Storage Box Battery User’s Guide | Pocket Clip Belt Clip Plastic Storage Box Battery User’s Guide | Pocket Clip Belt Clip Plastic Storage Box Battery User’s Guide |
Optional Accessories | Interface Kit Soft Case with Belt Clip Soft Case for Climber’s Harness Remote Vibrator Earphone | Interface Kit Soft Case with Belt Clip Soft Case for Climber’s Harness Remote Vibrator Earphone | Interface Kit Soft Case with Belt Clip Soft Case for Climber’s Harness Remote Vibrator Earphone |