You are browsing the BE_NL site. Would you like to be redirected to another country or region to see content and products specific to your location?

Snelle Offerte: Rohde & Schwarz FSV40 (1321.3008.40)

Rohde & Schwarz FSV40 (1321.3008.40)

FSV Signal and Spectrum Analyzer; 10 Hz to 40 GHz
Model
FSV40 (1321.3008.40)
Productgroep
RF & Microwave Spectrum Analyzers
Fabrikant
Rohde & Schwarz

Geconfigureerde modellen bevatten de volgende opties:

RF & Microwave Spectrum AnalyzersSpectrum Analyzers-Performance20GHz <= 50GHzDC <= 1kHzBenchtop
Configuraties
Belangrijke specificaties
Productoverzicht
Hulpbronnen

Kies uw configuratie

Show:

Beschikbare opties voor Rohde & Schwarz FSV40 (1321.3008.40)

Optie-IDBeschrijving
Accredited Calibration Coverage 4 Years from delivery for FSV40 w/o K54-Cal: - 1 scheduled R&S®Accredited- Calibration according to the 24 month recommended calibration interval - All necessary R&S®Accredited- Calibrations in case of repair or option upgrade
Accredited Calibration Coverage 4 Years from delivery for FSV40 with K54-Cal: - 1 scheduled R&S®Accredited- Calibration according to the 24 month recommended calibration interval - All necessary R&S®Accredited- Calibrations in case of repair or option upgrade
Accredited Calibration Coverage 5 Years from delivery for FSV40 w/o K54-Cal: - 2 scheduled R&S®Accredited- Calibrations according to the 24 month recommended calibration interval - All necessary R&S®Accredited- Calibrations in case of repair or option upgrade
Accredited Calibration Coverage 5 Years from delivery for FSV40 with K54-Cal: - 2 scheduled R&S®Accredited- Calibrations according to the 24 month recommended calibration interval - All necessary R&S®Accredited- Calibrations in case of repair or option upgrade
R&S®Accredited Calibration for FSV40 W/O K54-CAL - Accredited calibration certificate - ISO 17025 accredited and ISO 9001 certified, traceability to national/ international standards - Measurement of complete product specifications with the same procedures as used in production, incl. measurement uncertainties/ guardbanding - Documentation of calibration results upon receipt
R&S®Accredited Calibration for FSV40 WITH K54-CAL - Accredited calibration certificate - ISO 17025 accredited and ISO 9001 certified, traceability to national/ international standards - Measurement of complete product specifications with the same procedures as used in production, incl. measurement uncertainties/ guardbanding - Documentation of calibration results upon receipt
Extension of the 3 year standard product warranty to 4 years and Accredited Calibration Coverage for FSV40 w/o K54-Cal for 4 years: - 1 scheduled R&S®Accredited- Calibration according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Accredited-Calibrations after repair or option upgrade
Extension of the 3 year standard product warranty to 4 years and Accredited Calibration Coverage for FSV40 with K54-Cal for 4 years: - 1 scheduled R&S®Accredited- Calibration according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Accredited-Calibrations after repair or option upgrade
Extension of the 3 year standard product warranty to 5 years and Accredited Calibration Coverage for FSV40 w/o K54-Cal for 5 years: - 2 scheduled R&S®Accredited- Calibrations according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Accredited-Calibrations after repair or option upgrade
Extension of the 3 year standard product warranty to 5 years and Accredited Calibration Coverage for FSV40 with K54-Cal for 5 years: - 2 scheduled R&S®Accredited- Calibrations according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Accredited-Calibrations after repair or option upgrade
Calibration Coverage 4 Years from delivery for FSV40 w/o K54-Cal: - 1 scheduled R&S®Manufacturer- Calibration according to the 24 month recommended calibration interval - All necessary R&S®Manufacturer- Calibrations in case of repair or option upgrade
Calibration Coverage 4 Years from delivery for FSV40 with K54-Cal: - 1 scheduled R&S®Manufacturer- Calibration according to the 24 month recommended calibration interval - All necessary R&S®Manufacturer- Calibrations in case of repair or option upgrade
Calibration Coverage 5 Years from delivery for FSV40 w/o K54-Cal: - 2 scheduled R&S®Manufacturer- Calibrations according to the 24 month recommended calibration interval - All necessary R&S®Manufacturer- Calibrations in case of repair or option upgrade
Calibration Coverage 5 Years from delivery for FSV40 with K54-Cal: - 2 scheduled R&S®Manufacturer- Calibrations according to the 24 month recommended calibration interval - All necessary R&S®Manufacturer- Calibrations in case of repair or option upgrade
Extension of the 3 year standard product warranty to 4 years and Calibration Coverage for FSV40 w/o K54-Cal for 4 years: - 1 scheduled R&S®Manufacturer- Calibration according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Manufacturer-Calibrations after repair or option upgrade
Extension of the 3 year standard product warranty to 4 years and Calibration Coverage for FSV40 with K54-Cal for 4 years: - 1 scheduled R&S®Manufacturer- Calibration according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Manufacturer-Calibrations after repair or option upgrade
Extension of the 3 year standard product warranty to 5 years and Calibration Coverage for FSV40 w/o K54-Cal for 5 years: - 2 scheduled R&S®Manufacturer- Calibrations according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Manufacturer-Calibrations after repair or option upgrade
Extension of the 3 year standard product warranty to 5 years and Calibration Coverage for FSV40 with K54-Cal for 5 years: - 2 scheduled R&S®Manufacturer- Calibrations according to the 24 month recommended calibration interval - All repairs and all necessary R&S®Manufacturer-Calibrations after repair or option upgrade
Documentation of calibration values
Printout of DCV (additional, in combination with DCV-Option only)
USB mass memory write protection, disables writing to USB memory sticks (ex factory only) (for FSP, FSQ, FSU with WinXP+SP2 and FSV)
Option: Ruggedized housing with adjustable carrying handle (not retrofittable, not for rack mounting)
Option: AM/FM demodulator for listening; includes loudspeaker, plug for headphone and volume control
Option: OCXO, precision frequency reference Aging per year: 0.1 ppm Temp. drift: 0.1 ppm (5 to 45 °C)
Option: OCXO, precision frequency reference, aging per year: 0.1 ppm improved specification of temp. drift: 0.01ppm (5 to 40°C)
Option: Additional interfaces. IF/Video/AM-FM-demod. output, AUX port, trigger output, 2 additional USB(A) connectors
Tracking generator: for R&S®FSV7/13/30/40 (100 kHz-7 GHz); for R&S®ESR7 ( 9 kHz-7 GHz); for R&S®FSV3 (100 kHz-3,6 GHz); for R&S®ESR3 ( 9 kHz-3,6 GHz);
External generator control
Ultra high precision frequency reference Aging: < 4x10-9/year, retrofittable in Rohde & Schwarz service excludes R&S®FSV-B4 (hardware option)
Digital baseband interface, retrofittable, detector board Rev. 05.01 required, for R&S®FSV
Solid State Drive for R&S®FSV with FMR9 and Win7 including analyzer firmware, replaces standard hard disk (hardware option)
Solid state drive for R&S®FSV/FSVA with FMR11 and Win 7 including analyzer firmware, replaces standard hard disk (hardware option)
Solid state drive for R&S®FSV/FSVA with FMR11 and Win 10 including analyzer firmware, for exchange against standard hard drive (hardware option)
Second hard disk drive for FSV with FMR9 and Win7 including analyzer firmware, for exchange against standard hard drive (hardware option)
Second hard disk drive for FSV with FMR11 and Win7 including analyzer firmware, for exchange against standard hard drive (hardware option)
Second hard disk for R&S®FSV with FMR11 and Win10 including analyzer firmware, for exchange against standard hard drive (hardware option)
LO/IF connections for external mixers (FSV30 / FSV40)
RF Preamplifier 20 dB, 9 kHz to 7 GHz
RF preamplifier 9kHz to 40GHz (for R&S® FSV40 only) not installable post factory
Electronic attenuator, 1 dB steps (software license)
Freq extension to 10Hz
Extension to 40MHz signal analysis bandwidth
Extension to 160MHz signal analysis bandwidth, for R&S®FSV4 and R&S®FSV7, retrofittable in Rohde & Schwarz service (hardware option)
Extension to 160MHz signal analysis bandwidth, for R&S®FSV30 and R&S®FSV40, not for FSV40 model .39 retrofittable in Rohde & Schwarz service (hardware option)
Rack mount kit, preinstalled ex factory; for R&S®FSV/FSVR, excludes R&S®FSV-B1 (hardware option)
Analog modulation analysis for AM, FM, PM
Bluetooth/EDR measurement application (software license)
Power sensor measurement with NRP power sensors
Analysis of GSM, EDGE and EDGE evolution signals
Spectrogram measurement application
Noise figure and gain measurements (Preamplifier R&S®FSV-B22 or R&S®FSV-B24 required)
Phase noise measurement application
EMI application for diagnostic of RF interference with spectrum analyzers R&S®FSV and real-time spectrum analyzers R&S®FSVR, (software license)
Vector signal analysis application for modulation analysis of digital modulated single carrier signals (software license)
Analysis of 3GPP-FDD base station signals incl. HSPA+
3GPP-FDD UE analysis incl. HSPA
3GPP TD-SCDMA BTS measurements application
3GPP TD-SCDMA UE measurement application
Analysis of CDMA2000 base station signals
Analysis of 1xEV-DO base station signals
Analysis of WLAN 802.11a,b,g,j signals
WLAN 802.11ac measurement application, R&S®FSV-K91 required (software license)
Extension of R&S®FSV-K91 to 802.11n (R&S®FSV-K91 required)
Analysis of WIMAX™ 802.16 SISO signals
Analysis of EUTRA/LTE FDD downlink signals
Analysis of EUTRA/LTE FDD uplink signals
EUTRA/LTE Downlink MIMO measurement application (R&S®FSV-K100 or R&S®FSV-K104 required)
Analysis of EUTRA/LTE TDD downlink signals (software license)
Analysis of EUTRA/LTE TDD uplink signals
3GPP 5G-NR downlink Measurement Application IQ bandwidth > 100 MHz and 4 GB RAM required (software license)
Microwave preselector bypass for wideband demodulation above 7 GHz, only for R&S®FSVA40 (hardware option)
Extension of the 3 year standard product warranty to 4 years for FSV40 w/o K54-Cal: - All repairs and all necessary R&S®Manufacturer-Calibrations in case of repair
Extension of the 3 year standard product warranty to 4 years for FSV40 with K54-Cal: - All repairs and all necessary R&S®Manufacturer-Calibrations in case of repair
Extension of the 3 year standard product warranty to 5 years for FSV40 w/o K54-Cal: - All repairs and all necessary R&S®Manufacturer-Calibrations in case of repair
Extension of the 3 year standard product warranty to 5 years for FSV40 with K54-Cal: - All repairs and all necessary R&S®Manufacturer-Calibrations in case of repair

Toont 1 - 6 van 14 resultaten

1
2
3
1

Signal and spectrum analyzer 10Hz to 40GHz, -154dBm to +30dBm, resolution bandwidth 1Hz to 28(40)MHz

Product-ID: P-549228

FSV-B24 (1310.9616.40) • RF preamplifier 9kHz to 40GHz (for R&S® FSV40 only) not installable post factoryFSV-B17 (1310.9568.02) • Digital baseband interface, retrofittable, detector board Rev. 05.01 required, for R&S®FSVFSV-B4 (1310.9522.03) • Option: OCXO, precision frequency reference, aging per year: 0.1 ppm improved specification of temp. drift: 0.01ppm (5 to 40°C)FSV-B21 (1310.9597.02) • LO/IF connections for external mixers (FSV30 / FSV40)FSV-B25 (1310.9622.02) • Electronic attenuator, 1 dB steps (software license)
Huren

Bevestigd bij offerte

Offerte

Gebruikt

Beschikbaarheid wordt op de offerte vermeld

Inlichtingen

Financiele Oplossingen

Vraag nu om meer informatie

2

Signal and spectrum analyzer 10Hz to 40GHz, -154dBm to +30dBm, resolution bandwidth 1Hz to 28(40)MHz

Product-ID: P-222636

FSV-B4 (1310.9522.03) • Option: OCXO, precision frequency reference, aging per year: 0.1 ppm improved specification of temp. drift: 0.01ppm (5 to 40°C)FSV-B5 (1310.9539.02) • Option: Additional interfaces. IF/Video/AM-FM-demod. output, AUX port, trigger output, 2 additional USB(A) connectorsFSV-B25 (1310.9622.02) • Electronic attenuator, 1 dB steps (software license)FSV-B70 (1310.9645.02) • Extension to 40MHz signal analysis bandwidthFSV-B17 (1310.9568.02) • Digital baseband interface, retrofittable, detector board Rev. 05.01 required, for R&S®FSVFSV-B24 (1310.9616.40) • RF preamplifier 9kHz to 40GHz (for R&S® FSV40 only) not installable post factory
Huren

Bevestigd bij offerte

Offerte

Gebruikt

Beschikbaarheid wordt op de offerte vermeld

Inlichtingen

Financiele Oplossingen

Vraag nu om meer informatie

3

Signal and spectrum analyzer 10Hz to 40GHz, -154dBm to +30dBm, resolution bandwidth 1Hz to 28(40)MHz

Product-ID: P-245805

FSV-K30 (1310.8355.02) • Noise figure and gain measurements (Preamplifier R&S®FSV-B22 or R&S®FSV-B24 required)FSV-B29 (1310.9639.02) • Freq extension to 10HzFSV-K40 (1310.8403.02) • Phase noise measurement application
Huren

Bevestigd bij offerte

Offerte

Gebruikt

Beschikbaarheid wordt op de offerte vermeld

Inlichtingen

Financiele Oplossingen

Vraag nu om meer informatie

4

Signal and spectrum analyzer 10Hz to 40GHz, -154dBm to +30dBm, resolution bandwidth 1Hz to 28(40)MHz

Product-ID: P-644036

FSV-B29 (1310.9639.02) • Freq extension to 10HzFSV-B4 (1310.9522.02) • Option: OCXO, precision frequency reference Aging per year: 0.1 ppm Temp. drift: 0.1 ppm (5 to 45 °C)FSV-K9 (1310.8203.02) • Power sensor measurement with NRP power sensors
Huren

Bevestigd bij offerte

Offerte

Gebruikt

Beschikbaarheid wordt op de offerte vermeld

Inlichtingen

Financiele Oplossingen

Vraag nu om meer informatie

5

Signal and spectrum analyzer 10Hz to 40GHz, -154dBm to +30dBm, resolution bandwidth 1Hz to 28(40)MHz

Product-ID: P-236096

FSV-B17 (1310.9568.02) • Digital baseband interface, retrofittable, detector board Rev. 05.01 required, for R&S®FSVFSV-B21 (1310.9597.02) • LO/IF connections for external mixers (FSV30 / FSV40)FSV-B25 (1310.9622.02) • Electronic attenuator, 1 dB steps (software license)FSV-B4 (1310.9522.02) • Option: OCXO, precision frequency reference Aging per year: 0.1 ppm Temp. drift: 0.1 ppm (5 to 45 °C)FSV-B24 (1310.9616.40) • RF preamplifier 9kHz to 40GHz (for R&S® FSV40 only) not installable post factory
Huren

Bevestigd bij offerte

Offerte

Gebruikt

Beschikbaarheid wordt op de offerte vermeld

Inlichtingen

Financiele Oplossingen

Vraag nu om meer informatie

6

Signal and spectrum analyzer 10Hz to 40GHz, -154dBm to +30dBm, resolution bandwidth 1Hz to 28(40)MHz

Product-ID: P-236095

FSV-B5 (1310.9539.02) • Option: Additional interfaces. IF/Video/AM-FM-demod. output, AUX port, trigger output, 2 additional USB(A) connectorsFSV-B4 (1310.9522.02) • Option: OCXO, precision frequency reference Aging per year: 0.1 ppm Temp. drift: 0.1 ppm (5 to 45 °C)FSV-B21 (1310.9597.02) • LO/IF connections for external mixers (FSV30 / FSV40)FSV-B24 (1310.9616.40) • RF preamplifier 9kHz to 40GHz (for R&S® FSV40 only) not installable post factory
Huren

Bevestigd bij offerte

Offerte

Gebruikt

Beschikbaarheid wordt op de offerte vermeld

Inlichtingen

Financiele Oplossingen

Vraag nu om meer informatie

Toont 1 - 6 van 14 resultaten

1
2
3
* Prijzen en beschikbaarheid kunnen zonder voorafgaande kennisgeving worden gewijzigd. Alle prijzen kunnen variëren als gevolg van verzendvoorwaarden, btw of omzetbelasting, invoerrechten en wisselkoersen. Producten zijn mogelijk niet op alle locaties beschikbaar. Alle vermelde besparingen zijn gebaseerd op de volledige catalogusprijs van nieuwe instrumenten; werkelijke besparingen kunnen variëren op basis van optie (s), configuratie, wisselkoersen en andere factoren. Garantie kan variëren per categorie of specifiek beschikbaar product. Alle voorwaarden worden bevestigd door volledige schriftelijke offerte.

Kunt u niet vinden wat u zoekt?

Contact opnemen
Kunt u niet vinden wat u zoekt?
loader
loader logo