The Fluke 8845A 6 ½ digit precision multimeter handles your most demanding measurements on the bench or in a system. It measures volts, ohms, and amps, with basic V dc accuracy of up to 0.0024%, 10 A current range, and a wide ohms range. The 8845A also measures frequency and period. The functions of a counter, capacitance meter, and thermometer are built in. Graphical display modes include Trendplot™ paperless recorder mode, statistics and hist histograms.
Key Features |
6 ½ digit resolution |
Basic V DC accuracy of up to 0.0035% |
Dual display |
100 μA to 10 A current range, with up to 100 pA resolution |
Wide ohms range from 100 Ω to 100 MΩ with up to 100 μΩ resolution |
2 x 4 ohms 4-wire measurement technique |
Measure frequency and period |
Fluke 45 and Agilent 34401A emulation |
Graphical display |
Trendplot™ paperless recorder mode, statistics, histogram |
CAT I 1000 V, CAT II 600 V |
Specifications |
|
|
884xA Series
6.5 Digit Precision Multimeter
|
|
|
Modle Overview |
|
|
Model | 8845A | 8846A |
Display | VFD Dot Matrix | VFD Dot Matrix |
Resolution | 6.5 Digits | 6.5 Digits |
Measurement Function* |
|
|
V DC
Range
Max. Resolution
Accuracy
|
100 mV to 1000 V
100 nV
0.0035 + 0.0005
|
100 mV to 1000 V
100 nV
0.0024 + 0.0005
|
V AC
Range
Max. Resolution
Accuracy
Frequency
|
100 mV to 750 V
100 nV
0.06 + 0.03
3 Hz to 300 KHz
|
100 mV to 1000 V
100 nV
0.06 + 0.03
3 Hz to 300 KHz
|
Resistance
2 x 4 Wire
Range
Max. Resolution
Accuracy
|
Yes
100 Ω to 100 MΩ
100 µΩ
0.010 + 0.001
|
Yes
10 Ω to 1 GΩ
10 µΩ
0.010 + 0.001
|
A DC
Range
Max. Resolution
Accuracy
|
100 µA to 10 A
100 pA
0.050 + 0.005
|
100 µA to 10 A
100 pA
0.050 + 0.005
|
A AC
Range
Max. Resolution
Accuracy
Frequency
|
10 mA to 10 A
10 µA
0.10 + 0.04
3 Hz to 10 kHz
|
100 µA to 10 A
100 pA
0.10 + 0.04
3 Hz to 10 kHz
|
Freq/Period
Range
Max. Resolution
Accuracy
|
3 Hz to 300 kHz
1 µHz
0.01 %
|
3 Hz to 1 MHz
1 µHz
0.01 %
|
Continuity / Diode Test | Yes | Yes |
Capacitance
Range
Max. Resolution
Accuracy
|
--
--
--
|
1 nF to 0.1 F
1 pf
1 %
|
Temperature
Type
Range
Max. Resolution
Accuracy
|
--
--
--
|
Platinum RTD
-200 °C to +600 °C
0.01 °
0.06 °
|
Math Functions
(Zero, Min/Max/Average, Std Dev; mx+b)
dB/dBm
|
Yes
|
Yes
|
Advanced Functions
Statistics/Histogram
Trendplot
Limit Test
|
Yes
Yes
Yes
|
|
USB Memory | -- | USB Memory Drive Port |
Real Time Clock | -- | Yes |
Interfaces | RS-232
IEE-488.2
Ethernet
USB (with optional adapter)
| RS-232
IEE-488.2
Ethernet
USB (with optional adapter)
|
Programming Languages/Modes | SCPI (IEEE-488.2)
Agilent 34401A
Fluke 45
| SCPI (IEEE-488.2)
Agilent 34401A
Fluke 45
|
Weight | 3.6 kg
(8.0 lb)
| 3.6 kg
(8.0 lb)
|
Size (HxWxD) | 88 mm x 217 mm x 297 mm
(3.46 in x 8.56 in x 11.7 in)
| 88 mm x 217 mm x 297 mm
(3.46 in x 8.56 in x 11.7 in)
|
Safety | Designed to comply with;
IEC 61010-1 2000-1
ANSI/ISA-S82.01-1994
CAN/CSA-C22.2 No. 1010.1-92 CAT I 1000 V
CAT II 600 V
| Designed to comply with;
IEC 61010-1 2000-1
ANSI/ISA-S82.01-1994
CAN/CSA-C22.2 No. 1010.1-92 CAT I 1000 V
CAT II 600 V
|
Note:
* Accuracy, ± (% of reading + % of range), one year after calibration
Specifications |
|
884xA Series
6.5 Digit Precision Multimeter
|
|
Model Overview |
|
Models | Description |
8845A | 6.5 digit precision multimeter, 35 ppm |
8846A | 6.5 digit precision multimeter, 24 ppm USB memory |
Options and Accessories |
|
TL71 | Test Lead Set, Premium DMM |
TL910 | Precision Electronic Probe Set |
884X-SHORT | 4-Wire Short |
TL2X4W-PT | 2x4 Wire Ohms Test Lead 2 mm Probe Tip |
884X-RTD | 100 Ohm RTD Temperature Probe |
884X-512M | USB Memory 512 M |
884X-1G | USB Memory 1 GB |
Y8022 | IEEE488 cable (2 m) |
884X-USB | USB to RS232 cable adapter |
FVF-UG | FlukeView Forms Software Upgrade—No Cable |
Y8846 | Rack Mount Kit |