Megger S1-554


The  MGR-S1-554 insulation resistance tester (megger) is designed
specifically
to assist the user with the testing and maintenance of high voltage equipment.
Noise rejection of 4 mA rms at 200V is a standard feature. This
enables the instrument to take effective readings in high noise environments
such as high voltage substations and switchyards.

Automatic insulation resistance (IR), dielectric absorption ratio (DAR),
polarization index (PI), step voltage (SV), and dielectric discharge (DD)
tests
The S1-554 measurement range extends to 15 Tohm, and offers variable test
voltages of 50V to 1kV in 10 V steps and 1kV to 5kV in 25V steps.

The unit can operate on line or battery power.
Input voltage range is 95-240V +/-10% rms 50/60Hz.
Battery operation is rated at 6 hours continuous testing at 5kV.

The S1-554 has a large, easy-to-read backlit LCD making it equally suitable
for
use in both bright sunlight and poorly lit environments. Information displayed
includes resistance, voltage, leakage current, capacitance, battery status and
time constant. In addition, the elapsed time is displayed constantly, removing
the need for separate timers. It also allows up to 3 timed measurement
positions to be set, which simplifies DAR testing.

The  MGR-S1-554 is designed for testing the insulation of high-voltage
electric equipment. Its wide voltage range allows applications for low-voltage
equipment. Generators, motors, transformers, cables and switchgear all require
effective maintenance. The test techniques on the instruments provide valuable
diagnostic information.
- High-voltage power cables and high-voltage buses
- Large motor/generator windings
- Line and substation transformers

Performs spot tests, step-voltage tests, and dielectric absorption tests
for the following applications:
- Acceptance testing at an installation to check conformance to
specifications.
- Routine preventive/predictive maintenance testing after installation.
- Quality assurance testing as part of the manufacturing process.
- Diagnostic testing to isolate faulty components for repair.
- Contamination testing of service aged insulation.

The  MGR-S1-554 replaces the legacy models listed below.
Also see the  MGR-S1-552 for alternative with 2mA Noise Rejection.

Legacy Models:
BID-218650
 MGR-218651CL
AVO-S1-5010
LengthWidthHeightShip Wt 
0 " 0 " 0 " 0 lb  
    
N/A Currently not available for sale used
Need Configuration Assistance? Call our experienced Sales Staff.