Home >> Products >> KT-N9020A-503
 
Keysight Technologies (formerly Agilent) N9020A-503
Other Configurations. Call our experienced Sales Staff.
 

Keysight Technologies (formerly Agilent) N9020A-503

10Hz-3.6GHz MXA Spectrum Analyzer

 
browse
View Data Sheet PDF icon
Part NumberIncluded Options
Rent/Lease   Buy Used
KT-N9020A-503
MSRP: $31,809     Our USED Price: $15,905     
KT-N9020A-503/B25/EA3/P03/PFR/25MHz Analysis bandwidth/3.6GHz Electronic attenua/3.6GHz Preamplifier/Precision frequency refer
MSRP: $39,003     Our USED Price: $19,502     
KT-N9020A-503/B25/ESC/P03/PFR/25MHz Analysis bandwidth/External source control/3.6GHz Preamplifier/Precision frequency refer
MSRP: $37,466     Our USED Price: $18,733     
KT-N9020A-503/B25/P03/SW1/25MHz Analysis bandwidth/3.6GHz Preamplifier/N9073A1/N9073A2
MSRP: $49,529     Our USED Price: $24,765     
KT-N9020A-503/B25/SW1/N9075A/25MHz Analysis bandwidth/N9073A1/N9073A2/N9075A-2FP 802.16 OFDMA
MSRP: $60,128     Our USED Price: $30,064     
KT-N9020A-503/ESC/HW1/External source control/B25/EA3/P03/PFR
MSRP: $40,787     Our USED Price: $20,394     
KT-N9020A-503/HW1/SW2/WXP/B25/EA3/P03/PFR/N9068A/N9073A/N9075A/Windows XP OS
MSRP: $73,111     Our USED Price: $36,556     
KT-N9020A-503/B25/BBA/WXP/25MHz Analysis bandwidth/I/Q baseband inputs, ana/Windows XP OS
KT-N9020A-503/B25/P03/25MHz Analysis bandwidth/3.6GHz Preamplifier
KT-N9020A-503/B25/P03/PFR/25MHz Analysis bandwidth/3.6GHz Preamplifier/Precision frequency refer
KT-N9020A-503/B25/P03/SW6/25MHz Analysis bandwidth/3.6GHz Preamplifier/N9073A1-3/N9080A
KT-N9020A-503/B25/P03/WXP/25MHz Analysis bandwidth/3.6GHz Preamplifier/Windows XP OS
KT-N9020A-503/B25/SW7/25MHz Analysis bandwidth/N9072A,73A1,73A2,75,79A1
KT-N9020A-503/B25/WXP/25MHz Analysis bandwidth/Windows XP OS
KT-N9020A-503/BBA/EA3/P03/WXP/I/Q baseband inputs, ana/3.6GHz Electronic attenua/3.6GHz Preamplifier/Windows XP OS
KT-N9020A-503/EDP/Enhanced display package
KT-N9020A-503/HW1/W7X/B25/EA3/P03/PFR/Windows 7 OS
KT-N9020A-503/P03/WXP/3.6GHz Preamplifier/Windows XP OS
Catalog Description

Keysight Technologies (formerly Agilent) N9020A-503

10 Hz to 3.6 GHz MXA Spectrum Analyzer

  
Features:
Resolution Bandwidth (RBW):1Hz to 3MHz in 10% steps, 4,5,6,8MHz
Analysis bandwidth: 10MHz standard, 25MHz with option B25;
40MHz with option S40
DANL: -160dBm in 10Hz RBW with preamp (-149dBm without preamp)
Third Order Intercept (TOI): +12 dBm;
Phase Noise (1GHz Center Frequency):
-103dBc at 10kHz offset
-134dBc at 1MHz offset
Amplitude Accuracy:
Frequency Response: +-0.45dB, +-0.70dB with Preamp on;
Data Storage:
Internal 40GB nominal;
External storage supports USB 2.0 compatible memory devices;
RF input connector Type N (f) 50ohm;

Infiniium scope and InfiniiMax probes connectivity with option BBA

Interfaces:
USB 2.0, GPIB, and LAN (100BaseT)
LXI class-C compliant

Option HDD has been replaced by SSD and is standard on all units.

For USB Mouse use DELL-310-4073-MOUSE-USB/B
For USB Keyboard use DELL-310-3157-KB/USB/B
For USB DVR use PLEX-PX-716UF-DVDRW-COMBO

For rack mount 1CP:
See also KT-5063-9222 or KT-1CP005A
For rack mount 1CM
See KT-5063-9215 or KT-1CM013A.

For 1CN rack mount
See KT-5063-9228 or KT-1CN003A

Option Descriptions:
B40 requires DP2
CR3 Wideband IF output connector requires option DP2
CPR Programmable rear IF output Connector requires option DP2
EDP Enhanced Display Package, provide Spectrogram, Trace Zoom and Zone Span
DP2 Digital Processor, 2 GB Capture Memory
S40 requires option BBA.
PC2 Dual core processors ship on serial numbers >MY/US49100
SSD Is available on units with serial >US/MY/4910 or above and
with units that have option PC2 installed.

Internal Operating System:
WXP Windows XP Embedded Operating System
W7X Windows 7 Embedded Operating System
Options SSD and HDD require PC2.

Software descriptions and requirements:
N9061A used for N9061A-1FP 856XE/EC Compatibility application
N9063A used for N9063A-2FP Analog demodulation measurement application
N9068A used for N9068A-2FP Phase noise measurement application
N9069A used for N9069A-1FP Noise figure measurement application
N9071A used for N9071A-2FP GSM/EDGE Measurement application
N9072A used for N9072A-2FP cdma2000 Measurement application
N9073A1 used for N9073A-1FP W-CDMA Measurement application
N9073A2 used for N9073A-2FP HSDPA/HSUPA measurement application
requires N9073A1
N9075A used for N9075A-2FP WiMAX 802.16-OFDMA application
N9076A used for N9076A-1FP 1xEV-DO Measurement application
N9079A1 used for N9079A-1FP TD-SCDMA Measurement application
N9079A2 used for N9079A-2FP HSDPA/8PSK Measurement application
requires N9079A1
N9080A used for N9080A-1FP LTE Measurement application

ER defined bundles:

N1 is a bundle of:
N9068A Phase Noise measurement application
N9069A Noise Figure measurement application

HSPA is a bundle of:
N9073A1 W-CDMA Measurement application
N9073A2 HSDPA/HSUPA Measurement application
N9073A3 HSPA+ Measurement application

HW1 is a bundle of hardware options:
B25 25MHz Analysis Bandwidth
EA3 3.6GHz Electronic attenuator
P03 3.6GHz Preamplifier
PFR Precision frequency reference

HW2 is a bundle of hardware options:
EMC EMC Application
P03 3.6GHz Preamplifier
N9080A LTE Measurement Application

SW1 is a bundle of:
N9073A1 W-CDMA Measurement application
N9073A2 HSDPA/HSUPA Measurement application

SW2 is a bundle of:
N9068A Phase noise measurement application
N9073A/1FP W-CDMA Measurement application
N9073A/2FP HSDPA / HSUPA Measurement application
N9075A WiMax 802.16 OFDMA Measurement application

SW3 is a bundle of:
N9071A GSM/EDGE Measurement application
N9072A cdma2000 Measurement application
N9073A1 W-CDMA Measurement application
N9073A2 HSDPA/HSUPA Measurement application

SW4 is a bundle of:
N9072A cdma2000 Measurement application
N9073A1 W-CDMA Measurement application

SW5 is a bundle of:
N9068A Phase Noise Measurement application
N9073A1 W-CDMA Measurement application

SW6 is a bundle of:
N9073A1 W-CDMA Measurement application
N9073A2 HSDPA/HSUPA Measurement application
N9073A3 HSPA+ Measurement application
N9080A LTE-FDD Measurement application

SW7 is a bundle of:
N9072A cdma2000 Measurement application
N9073A1 W-CDMA Measurement application
N9073A2 HSDPA/HSUPA Measurement application
N9075A 802.16 OFDMA Measurement application
N9079A1 TD-SCDMA Measurement application


LengthWidthHeightShip Wt 
14.5 " 16.8 " 7 " 44 lb  
    
N/A Currently not available for sale used
Need Configuration Assistance? Call our experienced Sales Staff.