Home >> Products >> FLU-5522A
 
Other Configurations. Call our experienced Sales Staff.
 

Fluke Mfg Co 5522A

Multi Product Calibrator

 
browse
Part NumberIncluded Options
Rent/Lease   Buy Used
FLU-5522A 
FLU-5522A/PQ/SC1100/Power Quality Option/1.1GHz Scope Cal Option
Catalog Description

Fluke Mfg Co 5522A

 FLU-5522A Multi Product Calibrator.


The  FLU-5522A Multi-Product Calibrator addresses a wide calibration workload
and comes with internal and external protection features that protect it
against damage and make it easier to transport for on-site or mobile
calibration. The 5522A can also be fully automated with MET/CAL Plus
Calibration Management Software (version 7.3 SP1 or later). It is the ideal
calibrator for metrology professionals who need to perform resistance
calibration, voltage calibration, current calibration and more.

The  FLU-5522A calibrator covers many of the electronic test tools including:
Handheld and bench meters (analog and digital) up to 6 digits
Current clamps and clamp meters, Thermocouples and RTDs,
Process calibrators, Data loggers, Strip and chart recorders, Watt meters
Power harmonics analyzers, Panel meters, Graphical multimeters
Power quality analyzers (with option)
Analog or digital handheld and bench oscilloscopes to 600 MHz or 1.1 GHz (with
option)

General Specifications:
Warmup Time: Twice the time since last warmed up, to a maximum of 30 minutes.
Settling Time: Less than 5 seconds for all functions and ranges except as
noted.

Standard Interfaces: IEEE-488 (GPIB), RS-232
Line Power: Line Voltage (selectable): 100 V, 120 V, 220 V, 240 V
Line Frequency: 47 Hz to 63 Hz
Line Voltage Variation: +/- 10 % about line voltage setting
Power Consumption: 600 VA

Temperature
Operating: 0 C to 50 C
Calibration (tcal): 15 C to 35 C
Temperature Coefficient: Temperature coefficient for temperatures outside
tcal +/-5 C is 10 % of the stated specification per C.

Relative Humidity
Operating: <80 % to 30 C, <70 % to 40 C, <40 % to 50 C

Safety: IEC 61010-1: Overvoltage CATII, Pollution Degree 2
Output Terminal Electrical Overload Protection: Provides reverse-power
protection, immediate output disconnection, and/or fuse protection on the
output terminals for all functions. This protection is for applied external
voltages up to +/-300 V peak.
Analog Low Isolation: 20 V normal operation, 400 V peak transient
Electromagnetic Environment : IEC 61326-1: Controlled
Electromagnetic Compatibility: If used in areas with Electromagnetic fields
of 1 to 3 V/m from 0.08-1GHz, resistance outputs have a floor adder of 0.508?.
Performance not specified above 3 V/m
LengthWidthHeightShip Wt 
31 " 24 " 18 " 69 lb  
    
N/A Currently not available for sale used
Need Configuration Assistance? Call our experienced Sales Staff.