Elgar SW10500-1-3-2 EGR-SW10500-1-3-2 10.5 kVA Smartwave System 1/3 Phase Output Specifications: Power Factor of Load: 0 lagging to 0 leading AC or DC Output Voltage: 0 to 156 VRMS L-N, range 1; 0 to 312 VRMS L-N, range 2 AC or DC Output Current Per Phase: 25A to 135V in 156V range; 13A to 270V in 312V range Crest Factor: 4.0 (peak output current to RMS output current) Output Frequency Range: DC or 40 Hz to 5 kHz. For output frequencies greater than 1 kHz, the max slew rate allowed is 1 kHz per second. Output Power: 1750 VA: 1, 3500 VA: 1 or 2, 5250 VA: 1 or 3 (systems up to 21,000 VA) Max Total Harmonic Distortion (Full Linear Load or No Load): 0.25% max, 40 to 100 Hz; 0.5% max to 500 Hz; and 1% max to 1 kHz plus 1%/kHz to 5 kHz Load Regulation: 0.025% of full scale voltage for a full resistive load to no load; above 1 kHz, add 0.01%/kHz Line Regulation (DC, or 40 Hz to 5 kHz): 0.025% of full scale for a 10% input line change Voltage Accuracy: 0.1% of range. Above 1 kHz, add 0.2%/kHz. Add 0.1% of full scale for "AC PLUS DC" mode. Valid for 5 to 156 VRMS and 10 to 312 VRMS at 25C Voltage Resolution: 0.05% of full scale Frequency Resolution: 0.01 Hz: 40 Hz to 99.99 Hz 0.05 Hz: 100 Hz to 999.9 Hz 0.5 Hz: 1000 Hz to 5000 Hz Frequency Accuracy: 0.01% at 25C 0.001%/C Phase Accuracy, Phase-to-Phase Balanced Linear Resistive Load: 1, 40 Hz to 1 kHz, plus 1/kHz above 1 kHz Phase Angle Resolution: 0.1 Input Voltage Ranges: Factory configured 187 to 264 VRMS, 3 L-L (3 wire), or 342 to 457 VRMS, 3 L-L (4 wire). A chassis ground is also required. 115 or 230 VAC single-phase is required for PDU in 10.5-21 kVA systems. Input Frequency Range: 47 to 63 Hz
|