Home >> Products >> DOB-F6150-P1
 
Other Configurations. Call our experienced Sales Staff.
 

Doble F6150-P1

3 Phase Relay Test Set

 
browse
Part NumberIncluded Options
Rent/Lease   Buy Used
DOB-F6150-P1/6010/Controller
Catalog Description

Doble F6150-P1

 DOB-F6150-P1 Three Phase Power System Simulator




P1 configuration consists of the following bundle:

F6810 High Power Low Range Convertible.
F6885 GPS Receiver Interface.
F6895 GPS Receiver and Antenna.
F6909 Front Panel Interface.
F6910 Protest Interface.
F6825 Enhanced CPU2.
F6875 Variable Output Battery Simulator.

P1 version has Ethernet interface.


Maximum # of Sources: 12 (6 75VA voltage and 6 75VA current)
Multiple Ranges: Yes
Source Configuration: Internal
Voltage Sources
Output VA
3-Phase AC - 3*150VA @ 300V or
DC - 3*150W @ 424V
1-Phase AC L-N - 1*150VA @ 300V
1-Phase AC L-L - 1*300VA @ 600V
DC L-N - 1*150W @ 424V

Ranges (Res) - 75 Volts (0.01V)
150 Volts (0.01V)
300 Volts (0.01V)

Convertible Sources: Voltage to Current
Convertible Sources: Yes
Output VA Continuous:
3-Phase AC - 3*150VA
DC - 3*150Wat424V
1-Phase AC - 1*450VA
Output VA Transient Rating (Short-time 1.5 Seconds)
30% more power in transient range for 1.5 seconds
3-Phase AC - 3*195VA
1-Phase AC - 1*585VA
Ranges (Res) - 0.5, 1, and 2A @ 150VA
1.5, 3, and 6A @ 450VA
2x Range for 1.5 seconds @ 50% more power
Accuracy - 0.1% of reading typically
Distortion - 0.1% typical
2% maximum for all loads at full power
0-50 degrees C

Current Sources:
Output VA Continuous
3-Phase AC - 3*150VA @ 30A
1-Phase AC - 1*450VA @ 90A
DC L-N - 450W @ 60A

Output VA Transient Rating (Short-time 1.5 Seconds)
50% more power in transient range for 1.5 seconds
3-Phase AC - 3*225VA
1-Phase AC - 1*675VA
Ranges (Res) - 7.5, 15, 22.5A (0.0001A)
30, 40, 90A (0.01A)
2x Range for 1.5 seconds @ 50% more power
Accuracy - 0.1% of reading typically
Distortion - 0.1% typical
2% maximum for all loads at full power
0-50 degrees C

Phase Angle
Range - 0 to +-360 degrees
Resolution - 0.1 degrees at 50/60Hz
Accuracy - +- 0.25 degrees max at 50/60Hz
Frequency
Range Signals
Sinusoidal - 0.1kHz to 2kHz
Transient - dc, 3.0kHz
Resolution - 0.001 @ 50/60Hz
Accuracy - +- 0.00005 at 50/60Hz

DC Auxilliary
Battery Simulator - 48/125/250VDC 60W

Logic Input and Output
Inputs/Type - 8 Contacts Isolated Dry or 250V dc/ac
Outputs/Type - 8 Contacts Isolated
Meter Input for Measurement - Only for Transducer Testing

*Power Supply - 105-132 or 210-264 Selectable 50/60Hz

For users needing a PC, also see DELL-D600-PM755/60/1G/DC/MGWF
or similar in the ER Pool.
LengthWidthHeightShip Wt 
15 " 18 " 9.5 " 90 lb  
    
N/A Currently not available for sale used
Need Configuration Assistance? Call our experienced Sales Staff.