Doble F2253

450VA High Power Relay Test 1 Phase

 
browse
View Data Sheet
Part NumberIncluded Options
Rent/Lease   Buy Used
DOB-F2253/F2810/F2820/F2875/P/Fault Rotate/Delta Value/Delta Time/Battery Simulator/Protest Starter Kit
MSRP: $23,255     Our USED Price: Call     
Catalog Description

Doble F2253

Specifications: Note: One unit per phase required.
Mode 1: Source 1 Voltage; 150VA; Range:75,150,300V AC/DC

Source 2 Current: 450VA; Range:7.5,15,22.5,30,45,and 90A AC/DC
continuous.180A maximum for 1.5 seconds.

Mode 2: Source 1 Current: 150VA; Range: 7.5, 15, and 30A AC/DC continuous.

Source 2 Current: 300VA; Range: 7.5, 15, 30, 60A AC/DC continuous.
120A maximum for 1.5 seconds.

Installed Options:
F2810 Fault Rotate: Changes preset voltage and current phasors to
simulate A-N, B-N, C-N, and A-B, B-C, C-A faults without changing
interconnecting leads.
F2820 Delta Value/Delta Time: Simulates rate-of-change in frequency, at
least significant digit Hz per second rates for determining frequency relay
response to actual power system excursions. Also simulates rate-of-change of
voltage/current/phase angle with least significant digit per cycle for
realistic pickup and dropout test using AutoSensE (trademarked). Used with the
 DOB-F2010 Minicontroller (also in the ER pool).
F2875 Battery Simulator: An internal, high starting current 60W
continuous rating DC supply for powering protection relays and auxiliaries.
Select 48, 125, or 250VDC manually or use the POWER macro in PROTEST software.
(included in this configuration).

The following IEEE relays may be tested by the  DOB-F2253:
IEEE Device Number Relay Type: Number of Simulators: Sources:
2 Time-Delay Starting 1 1 VDC 1 IDC
21 Distance 1 Phase 1 1 VAC 1 IAC
21 Distance 3 Phase (Wye) 3 3 VAC 3 IAC
21 Distance 3 Phase (open Delta) 2 2 VAC 2 IAC
21G Ground Distance 3 3 VAC 3 IAC
24 Volts/Hz 1 1 VAC
25/25G Auto-Synchronizing 2 2 VAC
25/25G Synchronizing 2 2 VAC
27 AC/DC Under/Overvoltage 1 1 VAC
32 Directional Power 1 Phase 1 1 VAC 1 VAC
32 Directional Power 3 Phase
(open Delta, open Wye) 2 2 VAC 2 IAC
37/76 DC Under/Overcurrent 1 1 IDC
40 Loss of Field 1 1 VAC 1 IAC
or 1IDC
46 Phase Balance 2 3 IAC
46N Negative Sequence Overcurrent 1 1 IDC
47 Phase Sequence Voltage(open) 2 2 VAC
50 Instantaneous Overcurrent 1 1 IAC
(to 90A continuous,180A for 1.5sec)
51 Overcurrent(as above) 1 1 IAC
59 AC/DC Under/Overvoltage 1 1 VDC
67 Directional Overcurrent 1 1 VDC 1 IAC
67N Ground Dir.Overcurrent 1 1 VDC 1 IAC
79 AC Reclosing 2 2 VAC
81 Frequency 1 1 VDC
82 DC Reclosing 2 1 VDC
85 Carrier or Pilot Wire 1 1 IDC 1 VDC
86 Lock-out 1 1 VDC
87 Differential 1 2 IAC
87 Differential 3Phase 6 Current 3 6 IAC
94 Tripping 1 1 VDC 1 IAC

*Input Power Required: 105-132 V or 210-264 V (field selectable) at 47-63 Hz*