FOT-930 MaxTester - multifunction loss tester:
Delivers fully automated loss results in 10 seconds for up to three wavelengths, as well as automatic ORL and fiber-length measurements, with complete, high-quality test documentation.
Key Features |
FasTesT™: Three-wavelength measurement of optical loss, ORL and fi ber length in 10 seconds |
All-in-one, portable test solution: Up to eight instruments combined in a single, eye-catching handheld package |
FTTx-ready: Allows for the testing of passive optical networks (PONs) at 1310 nm, 1490 nm and 1550 nm, the three wavelengths recommended by the ITU-T (G.983.3) for PONs |
Cost of ownership: Lowest in the industry, thanks to three-year warranty, error-free testing and minimized training time |
Specifications |
|
FOT-930 Max Tester - Multifunction Loss Tester |
|
Ordering Information |
|
Model (FOT-93X) | Description |
FOT-932 | Ge detector, dual-wavelength 1310/1550 nm |
FOT-932-4 | Ge detector, triple-wavelength 1310/1550/1625 nm |
FOT-932-5 | Ge detector, triple-wavelength 1310/1490/1550 nm |
FOT-932X | GeX detector, dual-wavelength 1310/1550 nm |
FOT-932X-4 | GeX detector, triple-wavelength 1310/1550/1625 nm |
FOT-932X-5 | GeX detector, triple-wavelength 1310/1490/1550 nm |
FOT-933 | InGaAs detector, dual-wavelength 1310/1550 nm |
FOT-933-4 | InGaAs detector, triple-wavelength 1310/1550/1625 nm |
FOT-933-5 | InGaAs detector, triple-wavelength 1310/1490/1550 nm |
FOT-932-12C | Ge detector, dual-wavelength 1310/1550 nm (first port)
Dual-wavelength 850/1300 nm LED (50/125 µm) (second port)
|
FOT-932-12D | Ge detector, dual-wavelength 1310/1550 nm (first port)
Dual-wavelength 850/1300 nm LED (62.5/125 µm) (second port)
|
FOT-932X-12C | GeX detector, dual-wavelength 1310/1550 nm (first port)
Dual-wavelength 850/1300 nm LED (50/125 µm) (second port)
|
FOT-932X-12D | Ge detector, dual-wavelength 1310/1550 nm (first port)
Dual-wavelength 850/1300 nm LED (62.5/125 µm) (second port)
|
Talk Set and Visual Fault Locator (a) (FOT-93X-XX) |
|
00 | Without talk set and VFL |
VFL | With visual fault locator |
VFT | With talk set and VFL (universal 2.5 mm connector) |
Probe Option (FOT-93X-XX-XX) |
|
00 | Without probe |
FP4S | Inspection probe (400x) |
FP4D | Inspection probe (200x/400x) |
Connector* (FOT-93X-XX-XX) |
|
EI-EUI-28 | UPC/DIN 47256 |
EI-EUI-76 | UPC/HMS-10/AG |
EI-EUI-89 | UPC/FC narrow key |
EI-EUI-90 | UPC/ST |
EI-EUI-91 | UPC/SC |
EI-EUI-95 | UPC/E-2000 |
EI-EUI-98 | UPC/LC |
EA-EUI-28 | APC/DIN 47256 (c) |
EA-EUI-89 | APC/FC narrow key (c) |
EA-EUI-91 | APC/SC (c) |
EA-EUI-95 | APC/E-2000 (c) |
EA-EUI-98 | APC/LC (c) |
Notes:
* EXFO Universal Interface is protected by US patent 6,612,750
(a) Connector type for the talk set is the same as the one specified for the main source.
(b) Only available with second port/source.